Email
project@enertelindo.com

Call Us
+62 21 769-9511

Address
Jakarta, Indonesia

Instrumenation & Measurement Tools

Chauvin Arnoux

Download Catalog
Chauvin Arnoux

Founded in 1893 by Raphaël Chauvin and René Arnoux, Chauvin Arnoux has had a considerable influence on the development of measurement technology.

A long and prestigious list of inventions, such as the Universal Tester (the precursor of the multimeter) and the ammeter clamp, bears witness to this fact. Throughout the 20th century, Chauvin Arnoux filed more than 350 patents and trade marks.

These last few years have been marked by the gain of some impressive brand names such as Metrix, Pyro-Contrôle, Enerdis, Oritel and Radio Contrôle.

PRODUCTS

We mainly focus to distribute Chauvin Arnoux for industrial test and measurement.

Our Products

List of product in Chauvin Arnoux

  • Insulation Tester

    Insulation Tester

    Download Detail View
    • Wide measurement range from 10 k? to 30 T?
    • Fixed or programmable test voltage from 40 V to 10/15 kV
    • 5 mA charging current
    • Large backlit LCD screen with digital display, bargraphandR(t)+u(t),i(t) and i(u) graphs
    • Automatic calculation of DAR / PI / DD /?R (ppm/V) ratios
    • Multiple test modes: voltage ramp and step with “burning”, “early break” and “I-limit” modes
  • Tower Leg Ground Resistance Testing

    Tower Leg Ground Resistance Testing

    Download Detail View
    • Measurement range: 0.001 ?to 99.99 k? Resolution: 0.001 ?to 10 ?
    • Voltage: 16 to 32 VRMS
    • Frequency: 41 Hz to 5,018 Hz
    • Ground-rod resistance measurement: 0.01?to 100 k? IP53 protection
  • ULYS MCM Multi Channel Meter

    ULYS MCM Multi Channel Meter

    Download Detail View

    The solution for centralizing measurement on multiple electrical feeders

    • Compact : 18 three-phase meters in 1 
    • Quick implementation 
    • Compatible with a large number of sensors
  • Power Quality Analiser

    Power Quality Analiser

    Download Detail View
    • measure all the required voltage, current and power parameters for a full diagnosis of electrical installations
    • capture and record all parameters, transients, alarms, and wave forms simultaneously
    • easy way to use
    • 4 input voltages and 3/4 input currents
    • Voltage ratio up to 500 kV and Current ratio 100 mA to 6.500 A (including inrush mode)
  • Mapxxx Power Quality Monitor

    Mapxxx Power Quality Monitor

    Download Detail View
    • Networks : 3-Phase voltage, HF (2 MHz) transients, currents
    • Format : 160 x 240 x 90, without display
    • Compliant : with the EN61000-4-30, Standard Class A
    • Detection : of their fault location direction (up/downstream) for product with current
  • Enerium Power Monitor

    Enerium Power Monitor

    Download Detail View
    • Networks : LV / MV / HV
    • Format : 96x96 mm or 144x144 mm, with/without display
    • Multi Energy : Electrical, Water, gas, temperature 
    • Inputsandoutputs : Analogueand/ordigital(pulsesoralarms)
    • Recording : Time/date stamped of min and max values Up to 8 load curves, 1s to 60 minutes mean values Up to 4 trend curves: 5, 10, 12, 15, 20, 30, 60 minutes mean values
  • Transducer Triad 2

    Transducer Triad 2

    Download Detail View
    • Connection on single phase,3-phase balanced or 3-phase unbalanced 3/4 wires
    • 41Measurable electrical values(depending on model)
    • Accuracy class down to 0.1%
    • Up to 4 analogue outputs
    • Ethernet or RS485 output option Product status LEDs on front panel
  • Auxilary Relay

    Auxilary Relay

    Download Detail View

    Instantaneous contacts

    • Rated current: 10 A
    • Number of contacts: 4 CO
    • Type of contacts: AgCu3

    DC coil

    • DC voltage: 24Vdc
    • Operating range: 0.75 to 1.37 Un
    • Consumption: < 1 W in continuous operation
    • Control signal: continuous or pulsed ( > 50ms)
  • Flash Relay

    Flash Relay

    Download Detail View

    Flashing frequency: 55 to 90 pulses / min (fixed frequency) Instantaneous contact

    • Rated current: 12 A
    • Number of contacts: 2 CO
    • Type of contacts: AgCdO

    AC/DC coil

    • AC/DC voltage: 24, 48, 110, 230
    • Operating range: 0.8 to 1.2 Un
    • Consumption: 5 W
  • Clamp Meter

    Clamp Meter

    Download Detail View
    • Diameter clamp 35 mm
    • Measure Ground voltage, leakage current, and impedance
    • Loop resistance measurement from 0.01 to 1500 Ohm
    • Measurement of grounding inductance from 10 to 500 uH
    • Measurement of leakage current from 0.2 mA to 40 A

Search Product